Supertek RO Systems for industrial use.

Industrial RO – Supertek 50 LPH SS

Product Description

Supertek 50 LPH SS

 

Basics of Design & Water Treatment

 

PLANT INTRODUCTION

This produces quality water at the flow rate of 50 litres per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system.

 

RAW WATER ANALYSIS

This water treatment system is based on the following water analysis:
Sl. No. Parameter Analysis Value
1.
Total Dissolved Solids (TDS) 2000 ppm
2.
Turbidity 1 NTU
3.
SDI 4
4.
Heavy Metals nil
5.
Organics And Bacteria nil
6.
Oil And Grease nil
7.
Residual Chlorine nil
8.
Temperature < 40˚C
9.
Color Colorless
10.
Odour Very Less Odour
11.
BOD & COD nil
12.
Total Hardness 850 PPM

 

END WATER QUALITY

Sl. No. Parameter Analysis Value
1.
Total Dissolved Solids (TDS) < 100 ppm
2.
PH 7.0 ± 0.2
3.
Turbidity nil
4.
Color nil
5.
Hardness < 50 ppm

 

RO PLANT OPERATING CONDITION

Sl. No. Parameter Analysis Value
1.
Feed Flow Rate 125 Ltr
2.
Product Flow Rate 50 LPH
3.
Rejest Flow Rate 75 LPH
4.
Recovery 35 % to 40 %

 

TREATMENT SCHEME

Sl. No. Description
Raw Water Storage Taken (By Client)
1.
Raw Water Transfer Pump
2.
Multi–Grade Filter
3.
Activated Carbon Filter
4. Antiscalant Dosing System
5. Micron Filter ( 20 micron & 5 micron )
6. High Pressure Pump
7. RO Module (Membrane & Membrane Housing)
8. Flushing/Cleaning System
Products (Pure) Water Storge Tank (By Client)

 

The end water quality is achieved subject to:

  • Feed quality should be same as required. In case of any change in the quality of raw water, the same may have an implication on the operating parameters and End-Water quality of the system.
  • Feed limiting is an implication on the operating parameter and end water quality of the system.
  • Feed limiting condition is to be strictly maintained and operation of the water treatment plant should be strictly followed in totality as per the operating manual and instructions.

 

TECHNICAL SPECIFICATION

RO 50 LPH
Product Capacity
50 lph
Weight
33 Kg
Dimension (L x W x H)
500mm X 325mm X 862mm
Booster Pump
Diaphragm Type
Adopter 36 VDC
Membrane 75/100 GPD
See also different:Industrial RO