Supertek RO Systems for industrial use.
Industrial RO – Supertek 50 LPH SS
Product Description
Basics of Design & Water Treatment
PLANT INTRODUCTION
This produces quality water at the flow rate of 50 litres per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system. |
RAW WATER ANALYSIS
This water treatment system is based on the following water analysis: |
Sl. No. | Parameter | Analysis Value |
1.
|
Total Dissolved Solids (TDS) | 2000 ppm |
2.
|
Turbidity | 1 NTU |
3.
|
SDI | 4 |
4.
|
Heavy Metals | nil |
5.
|
Organics And Bacteria | nil |
6.
|
Oil And Grease | nil |
7.
|
Residual Chlorine | nil |
8.
|
Temperature | < 40˚C |
9.
|
Color | Colorless |
10.
|
Odour | Very Less Odour |
11.
|
BOD & COD | nil |
12.
|
Total Hardness | 850 PPM |
END WATER QUALITY
Sl. No. | Parameter | Analysis Value |
1.
|
Total Dissolved Solids (TDS) | < 100 ppm |
2.
|
PH | 7.0 ± 0.2 |
3.
|
Turbidity | nil |
4.
|
Color | nil |
5.
|
Hardness | < 50 ppm |
RO PLANT OPERATING CONDITION
Sl. No. | Parameter | Analysis Value |
1.
|
Feed Flow Rate | 125 Ltr |
2.
|
Product Flow Rate | 50 LPH |
3.
|
Rejest Flow Rate | 75 LPH |
4.
|
Recovery | 35 % to 40 % |
TREATMENT SCHEME
Sl. No. | Description |
Raw Water Storage Taken (By Client) | |
1.
|
Raw Water Transfer Pump |
2.
|
Multi–Grade Filter |
3.
|
Activated Carbon Filter |
4. | Antiscalant Dosing System |
5. | Micron Filter ( 20 micron & 5 micron ) |
6. | High Pressure Pump |
7. | RO Module (Membrane & Membrane Housing) |
8. | Flushing/Cleaning System |
Products (Pure) Water Storge Tank (By Client) |
The end water quality is achieved subject to:
- Feed quality should be same as required. In case of any change in the quality of raw water, the same may have an implication on the operating parameters and End-Water quality of the system.
- Feed limiting is an implication on the operating parameter and end water quality of the system.
- Feed limiting condition is to be strictly maintained and operation of the water treatment plant should be strictly followed in totality as per the operating manual and instructions.
TECHNICAL SPECIFICATION
RO 50 LPH | |
Product Capacity
|
50 lph |
Weight
|
33 Kg |
Dimension (L x W x H)
|
500mm X 325mm X 862mm |
Booster Pump
|
Diaphragm Type |
Adopter | 36 VDC |
Membrane | 75/100 GPD |
See also different: | Industrial RO |